Acoustic materials work through their properties, thickness, mounting, coverage, and placement. A product name alone cannot predict how a finished room will sound.
Thoughtful acoustic planning begins with the room.
ACOUSTIC SYSTEMS / ROOM + ASSEMBLY
Room absorption and sound isolation do different jobs
Absorption reduces reflected sound within a room. Isolation addresses sound transmitted through the complete construction, including wall, door, ceiling, gaps, and flanking paths. Ordinary acoustic panels do not automatically soundproof a room.
01
Absorption is not isolation
Absorptive materials reduce reflected sound energy within a room, helping manage reverberation. Sound isolation limits transmission between spaces and depends on the complete construction: mass, airtightness, decoupling where appropriate, penetrations, doors, and flanking paths.
02
Common absorptive and scattering systems
Fabric-wrapped porous panels, ceiling clouds, baffles, bass traps, and engineered perforated or slatted products address different frequency ranges and room conditions. Diffusers scatter sound rather than removing the same amount of energy.
Wall panels and clouds: reflection control with placement and coverage matched to the room.
Baffles: suspended absorbers that can suit tall spaces when clearances and services allow.
Wood-slat or perforated systems: rely on engineered openings and suitable absorptive backing; appearance alone does not establish performance.
Bass traps and diffusers: specialized options when low-frequency behavior or scattering is part of the brief.
03
Sound-isolation assemblies
Walls, doors, glazing, ceilings, penetrations, and mechanical paths may need coordinated construction changes to limit transmission. Isolation work differs from installing decorative absorbers and should be evaluated by qualified specialists when required.
04
Selection and care
Start with the acoustic purpose, then confirm that the tested configuration and installation suit the room. Appearance alone does not establish acoustic performance.
Match frequency range, thickness, coverage, mounting, and placement to the project question.
Review aesthetic fit, durability, impact resistance, cleaning, and maintenance for the room’s actual use.
Coordinate substrates, fixings, access, ceiling services, moisture, and construction conditions.
Confirm required fire performance, accessibility clearances, and applicable safety needs with the responsible project team.
05
Performance data and project fit
Compare tested absorption data for the intended mounting and frequency range, and confirm the test method and product configuration. Fire ratings, durability, cleanability, and code suitability should be verified for each project; this page does not endorse a specific product or rating.
06
Absorption ratings
Frequency-dependent absorption coefficients show how a tested specimen performs across frequency bands. NRC (Noise Reduction Coefficient) and SAA (Sound Absorption Average) summarize test results into single numbers; neither replaces the full frequency data or predicts every installed room.
ASTM C423 is a reverberation-room test method for sound absorption and sound-absorption coefficients.
Compare the product’s tested thickness, mounting, air gap, and configuration with the intended installation.
A higher single-number absorption rating is not a sound-isolation rating.
07
Sound-transmission ratings
STC (Sound Transmission Class) classifies airborne sound-transmission performance for a tested building assembly. ASTM E90 is a laboratory method for measuring airborne transmission loss; ASTM E413 describes the STC classification. These ratings do not describe how well a decorative panel absorbs reflections.
Review the tested assembly, including its layers, joints, penetrations, and mounting.
A wall rating does not guarantee the same performance in the field; doors, ceilings, services, and flanking paths matter.
08
Safety and suitability
Confirm fire-performance documentation, building-code requirements, moisture resistance, cleaning method, durability, accessibility clearances, healthcare hygiene requirements, and the manufacturer’s installation instructions with the responsible project team. No product is represented here as fire-rated or code-compliant without project-specific documentation.
Qualitative guide
Compare the job, not just the product name.
Typical acoustic system uses and project considerations; no performance values are implied.
System
Typical purpose
Check before specifying
Fabric-wrapped wall panels
Control selected room reflections
Frequency data, thickness, coverage, mounting, fabric care
Ceiling clouds or baffles
Add overhead absorption in suitable spaces
Suspension, clearances, services, fire and maintenance needs
Slatted or perforated systems
Combine a finish with an engineered absorptive backing
Tested assembly, backing, cavity, cleaning and installation details
Bass traps or diffusers
Address low-frequency behavior or scatter reflections where appropriate
Room purpose, placement, dimensions, tested design information
Sound-isolation assemblies
Reduce transmission through a complete building separation
Mass, airtightness, decoupling, doors, penetrations and flanking
Take the next step
Every room has its own story.
Tell us what you are hearing, and we can help you decide what to look at first.